Acson ACM25E Especificaciones

Busca en linea o descarga Especificaciones para Acondicionadores de aire del sistema de división Acson ACM25E. Acson ACM25E Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 72
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Ceiling Convertible
Split Systems
ACM - E- 2006
A5CM 20 E/ER
A5CM 25 E/ER
A5CM 28 E/ER
Models:
Vista de pagina 0
1 2 3 4 5 6 ... 71 72

Indice de contenidos

Pagina 1 - Split Systems

Ceiling ConvertibleSplit SystemsACM - E- 2006A5CM 20 E/ERA5CM 25 E/ERA5CM 28 E/ERModels:

Pagina 2 - CONTENTS

General Data - Heatpump (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED A

Pagina 3 - 1. NOMENCLATURE

General Data - Heatpump (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED A

Pagina 4

10Electrical Data - Cooling Only (R410A)A5LC 20C A5LC 25CPOWER SOURCE V/Ph/HzRATED INPUT POWER W101 109RATED RUNNING CURRENT A0.46 0.49MOTOR OUTPUT W5

Pagina 5 - 2. FEATURES

11Electrical Data - Heatpump (R410A)A5CM 20ER A5CM 25ERA5LC 20CR A5LC 25CRPOWER SOURCE V/Ph/HzRATED INPUT POWER W101 109RATED RUNNING CURRENT A0.46 0.

Pagina 6 - 3. PRODUCT LINE UP

12Components Data (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.A5CM 20E A5CM 25EA5LC 20C A5LC 25Cmm/i

Pagina 7 - A5LC-C SERIES PRODUCT LINE UP

13Components Data (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.A5LC 28C A5LC 35Cmm/inmm/inmm/in457 /

Pagina 8

14Components Data (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.A5CM 20ER A5CM 25ERA5LC 20CR A5LC 25CR

Pagina 9

15Components Data (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.A5LC 28CR A5LC 35CRmm/inmm/inmm/in457

Pagina 10

16Safety Devices1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.A5CM 20E A5CM 25EA5LC 20C A5LC 25COPEN kPa / ps

Pagina 11

5. OPERATING RANGEEnsure the operating temperature is in allowable range.Cooling onlyHeatpump17 Caution :The use of your air conditioneroutside t

Pagina 12 - CONFIRMATION

CONTENTS1. NOMENECLATURE ... 12. FEATURES ...

Pagina 13

6. PERFORMANCE TABLE18Interpolation and Extrapolation method can be used to get the total capacity, TC and sensible capacity, SCat those temperatures

Pagina 14 - Components Data (R410A)

19Details:1st Step:To obtain the Total capacity and Sensible capacity for(a) Indoor Condition: 24°C DB, 15°C WB Outdoor Condition: 35°C DBTotal ca

Pagina 15

202nd Step:To obtain the Total capacity and Sensible capacity for(a) Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 35°C DBTotal capacity,

Pagina 16

213rd Step:To obtain the Total capacity and Sensible capacity for(a) Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 37°C DBTotal capacity,

Pagina 17

22R410A MODELS(COOLING ONLY)MODEL : A5CM 20E / A5LC 20CMODEL : A5CM 25E / A5LC 25CTC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW

Pagina 18 - Safety Devices

23R410A MODELS(COOLING ONLY)MODEL : A5CM 28E / A5LC 28CMODEL : A5CM 28E / A5LC 35CTC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW

Pagina 19 - 5. OPERATING RANGE

24R410A MODELS(HEATPUMP)MODEL : A5CM 20ER / A5LC 20CRCOOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(

Pagina 20 - 6. PERFORMANCE TABLE

25R410A MODELS(HEATPUMP)MODEL : A5CM 25ER / A5LC 25CRCOOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(

Pagina 21

26R410A MODELS(HEATPUMP)MODEL : A5CM 28ER / A5LC 28CRCOOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(

Pagina 22

27R410A MODELS(HEATPUMP)MODEL : A5CM 28ER / A5LC 35CRCOOLING MODEHEATING MODETC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(

Pagina 23

1A CM 20ERBrandA : AcsonCapacity20 : 20,000 Btu/hSeriesE : E seriesModel TypeR : heatpumpOmitted if Cooling OnlyG IA C A-Refrigerant5 : R410AOmitted i

Pagina 24 - R410A MODELS

7. OUTLINES AND DIMENSIONS28INDOOR UNITA5CM 20/25/28E/EROUTDOOR UNITA5LC 20/25/28C/CRMODEL A B C D E F G H I J K L M N O P Q R S T855 628 328 508 181

Pagina 25 - MODEL : A5CM 28E / A5LC 35C

A5LC 35C/CRNote : Dimension in mm29

Pagina 26 - HEATING MODE

8. REFRIGERANT CIRCUIT DIAGRAMSMODEL : A5CM 20E - A5LC 20CMODEL : A5CM 25E - A5LC 25CA5CM 28E - A5LC 28C30

Pagina 27 - MODEL : A5CM 25ER / A5LC 25CR

31MODEL : A5CM 28E - A5LC 35CMODEL : A5CM 20ER - A5LC 20CR

Pagina 28 - MODEL : A5CM 28ER / A5LC 28CR

MODEL : A5CM 25ER - A5LC 25CR32MODEL : A5CM 28ER - A5LC 28CR

Pagina 29 - MODEL : A5CM 28ER / A5LC 35CR

MODEL : ACM 28ER - ALC 30CR33MODEL : A5CM 28ER - A5LC 35CR

Pagina 30 - 7. OUTLINES AND DIMENSIONS

INDOOR UNITMODEL: A5CM 20/25E (WITH IONIZER)OUTDOOR UNITMODEL: A5LC 20/25C34

Pagina 31 - Note : Dimension in mm

35INDOOR UNITMODEL: A5CM 28E (WITH IONIZER)OUTDOOR UNITMODEL: A5LC 28C

Pagina 32 - A5CM 28E - A5LC 28C

36INDOOR UNITMODEL: A5CM 28E (WITH IONIZER)OUTDOOR UNITMODEL: A5LC 35C

Pagina 33 - MODEL : A5CM 20ER - A5LC 20CR

37HEATPUMPINDOOR UNITMODEL: A5CM 20/25ER (WITH IONIZER)OUTDOORMODEL: A5LC 20/25CR

Pagina 34 - MODEL : A5CM 28ER - A5LC 28CR

2A LC 20 C RBrandA : AcsonCapacity20 : 20,000 Btu/hSeriesC : C seriesModel TypeR : heatpumpOmitted if Cooling5 P OA C A-Refrigerant5 : R410AOmitted if

Pagina 35 - MODEL : A5CM 28ER - A5LC 35CR

38INDOOR UNITMODEL: A5CM 28ER (WITH IONIZER)OUTDOOR UNITMODEL: A5LC 28CR

Pagina 36 - MODEL: A5LC 20/25C

39INDOOR UNITMODEL: A5CM 28ER (WITH IONIZER)OUTDOOR UNITMODEL: A5LC 35CR

Pagina 37 - MODEL: A5LC 28C

10. CONTROLLER40G12 REMOTE CONTROLLERTemperature Settingx To set the desired roomtemperature, press the button toincrease or decrease the settemperatu

Pagina 38 - MODEL: A5LC 35C

411. “ON/OFF” switchx Press to start the air conditioner unit.x Press again to stop the unit.2. Temperature settingx Set the desired room temperature.

Pagina 39 - MODEL: A5LC 20/25CR

COOL DRY FAN HEAT42Normal Operation / Fault Indication|Cool modeHeat modeAuto mode in heating operationAuto mode in cooling operationDry modeOutdoor c

Pagina 40 - MODEL: A5LC 28CR

43Wired Remote Control – SLMCooling / Heatpump ModelError Code at 7 Segment Display Operation / Faulty IndicationBlink E1 Room sensor open or shortBli

Pagina 41 - MODEL: A5LC 35CR

11. INSTALLATIONSharp edges and coil surfaces are potential injury hazard. Avoid from contact with them.Caution(1) Installation of Indoor UnitPrelimin

Pagina 42 - 10. CONTROLLER

45Please ensure that the following steps are taken:x Check the gradient for drainage flow as recommended in Figure B.x Provide clearance for easy serv

Pagina 43 - SLM AC-5300 (OPTIONAL)

46Under Ceiling InstallationInstall the Suspension Bolts1. Install the suspension bolts so that it can support the indoor unit.2. Adjust the distance

Pagina 44 - COOL DRY FAN HEAT

471. Refer to the dimension as illustrated when installing the mounting bracket.2. Determine the pipe hose position using the rear piping hole. Drill

Pagina 45 - Phase Sequencer

2. FEATURESCEILING AND FLOOR INSTALLATION OPTIONThe unit is uniquely designed with the option to install either below the ceiling or mounted at low wa

Pagina 46 - 11. INSTALLATION

48Piping and Drain Hose InstallationUnder Ceiling Type1. The piping direction can be 2 ways as illustrated.2. The drain hose is only 1 way.Floor stand

Pagina 47 - Floor standing type

49How to Remove the Air Inlet Grille1. Remove the air inlet grille by both hands as the direction shown.2. Loosen the screws for fixing the panel arm

Pagina 48

50How to install the air filterTo Adjust the Vane DirectionAdjust the vane linkage as the direction shown to get the required vane direction.Dimension

Pagina 49 - Floor standing installation

(2) INSTALLATION OF OUTDOOR UNITAs condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achieve maximum

Pagina 50

IndoorOutdoor15 15 15 458882510 10 10 10Maximum No. of BendsModelMaximum Length, mMaximum Elevation, mModelLiquid (mm/in)6.35 / 1/46.35 / 1/49.52 / 3/

Pagina 51

53(4) WIRINGELECTRICAL CONNECTIONSx Wiring regulations on wire diameters differ from country to country. Please refer to your LOCAL ELECTRI-CAL CODES

Pagina 52 - To Adjust the Vane Direction

54Diagram shows typical charging method:(7) OVERALL CHECKINGx Ensure the following, in particular:1. The unit is mounted solidly and rigid in position

Pagina 53 - INSTALLATION CLEARANCE

55(9) SPECIAL PRECAUTIONS WHEN DEALING WITH REFRIGERANT R410A UNITi) WHAT IS NEW REFRIGERANT R410A?R410A is a new HFC refrigerant which does not damag

Pagina 54 - (3) REFRIGERANT PIPING

d) When charging R410A, ensure that only liquid is being withdrawn from the cylinder or can. This is toensure that only the original composition of R4

Pagina 55 - 94 / 95289 / 292

12. SERVICING AND MAINTENANCE57Warning : Disconnect from main supply before servicing the air conditionerThe unit is designed to give long life operat

Pagina 56 - R410A - Nil

3. PRODUCT LINE UPINDOOR UNITACM-E SERIES PRODUCT LINE UPA5CM-E SERIES PRODUCT LINE UP4Control ModuleFinL2SLM3Netware IIIG12 HandsetCE MarkW/out Marki

Pagina 57

58PRE START UP MAINTENANCE(AFTER EXTENDED SHUTDOWN)– Inspect thoroughly and clean indoor and outdoor units.– Clean or replace air filters.– Clean cond

Pagina 58 - Invert cylinder

When a malfunction of the air conditioner unit is detected, immediately switch off the main power supplybefore proceeding with the following troublesh

Pagina 59

Diagnostic GuidelinesBy means of pressure reading:60 Pressure Data Circuit Too low A little low Normal A little high Too high Probable cause High s

Pagina 60

By means of diagnostic flow chart:Generally, there are two kinds of problems, i.e. starting failure and insufficient cooling/heating. “Starting failur

Pagina 61

62ii ) Diagnosis of Refrigerant Circuit / ApplicationThere might be some causes where the unit starts running but does not perform satisfactorily, i.e

Pagina 62 - Diagnostic Guidelines

63Satisfactory operation with temperature difference of air intake & discharge of indoor unit14°C to 20°C. *( * value is for reference only )

Pagina 63

14. EXPLODED VIEW & PARTS LIST64MODEL: A5CM 20/25/28E/ERNo Description Part No No Description Part No1 Assy., Top Panel A50124074907 9 Blower Whee

Pagina 64

65MODEL: A5LC 20CNo Description Part No No Description Part No1 Assy. Base Pan 9 Back Panel, Right A01014070599ALC 18C A50014077978 10 CompressorALC 2

Pagina 65 - 14°C to 20°C. *

MODEL: A5LC 25 / 28C66No Description Part No No Description Part No1 Assy. Base Pan A50014073884 9 Back Panel, Right A010140709502 Assy. Outdoor Coil

Pagina 66 - MODEL: A5CM 20/25/28E/ER

67MODEL: A5LC 20CRNo Description Part No No Description Part No1 Assy. Base Pan 10 CompressorALC 20CR A50014073884 ALC 20CR A04019018334A5LC 20CR A500

Pagina 67 - MODEL: A5LC 20C

5OUTDOOR UNITA5LC-C SERIES PRODUCT LINE UPGrilleCap. TubeTXVGold FinHigh Ambient KitLow Ambient KitContactorHigh Pressure SwitchLow Pressure SwitchNan

Pagina 68 - MODEL: A5LC 25 / 28C

68MODEL: A5LC 25 / 28CRNo Description Part No No Description Part No1 Assy. Base Pan A50014073884 10 Compressor2 Assy. Outdoor Coil ALC 25CR A04019019

Pagina 69 - MODEL: A5LC 20CR

69MODEL: A5LC 35 C/CRNo Description Part No No Description Part No1 Assy. Base Pan A50014053238 10 Assy. Coil2 Assy. Flare Valve 3/8" ALC 30C A50

Pagina 70 - MODEL: A5LC 25 / 28CR

While upmost care is taken in ensuring that all details in the publication are correct at time of going to press, we are constantly striving forimprov

Pagina 71 - MODEL: A5LC 35 C/CR

6General Data - Cooling Only (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TEST

Pagina 72

7General Data - Cooling Only (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TEST

Comentarios a estos manuales

Sin comentarios